TY - JOUR
T1 - A Novel ultrasensitive nitrite ion detection using tungsten trioxide-modified gold electrode
AU - Sari, Niken Puspita
AU - Mulyawati, Mulyawati
AU - Syahputra, Muhammad Yudha
AU - Madurani, Kartika A.
AU - Kurniawan, Fredy
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2024/9/1
Y1 - 2024/9/1
N2 - A novel ultrasensitive nitrite ion detection using tungsten trioxide/carbon (WO3/C) modified gold electrode has been studied. The WO3 was synthesized from tungsten metal through chemical methods with selective precipitation techniques. The visual color of the material obtained is bright yellow, indicating WO3 compound. The X-ray diffraction (XRD) diffractogram confirms WO3 compound in monoclinic shaped by showing of the 2θ at 23.205, 23.723, 24.384, 33.426, and 33.911. The characterization using Field Emission Scanning Electron Microscopy (FESEM) showed that the material obtained was a disk-shaped with diameter 150–250 nm and a thickness of 50 nm. The Energy Dispersive X-ray spectroscopy (EDX) also confirms WO3 compound with no impurities. The gold electrode was modified by dip immersion technique where the gold electrode was dipped in a mixture of WO3-carbon paste. The measurement of surface area by cyclic voltammetry shows that the WO3/C modified gold electrode has the highest surface area compared to unmodified gold and C-modified gold electrode, indicating it has more active electron transfer sites. The WO3/C modified gold electrode worked well at pH 7 for the detection of nitrite ion and gave the highest peak current (0.875 V) than the others. The measurement ranges from 1–200 mg/L with no interference from NO3−, SO42−, Zn2+, Fe2+, Pb2+, Cl−, Ca2+, and NH4+ ions. The sensitivity and the LOD of the electrode are 8.86 μA.L.mg−1.cm−2 and 0.8 µg/L, respectively. The proposed method not only exhibits identical precision and accuracy to the standard method in detecting nitrite ions in real samples but also offers the advantages of rapid analysis, uncomplicated pretreatment procedures, environmental friendliness, and economical operation. This performance indicates that the WO3/C modified gold electrode is feasible as an alternative electrode for nitrite ion detection.
AB - A novel ultrasensitive nitrite ion detection using tungsten trioxide/carbon (WO3/C) modified gold electrode has been studied. The WO3 was synthesized from tungsten metal through chemical methods with selective precipitation techniques. The visual color of the material obtained is bright yellow, indicating WO3 compound. The X-ray diffraction (XRD) diffractogram confirms WO3 compound in monoclinic shaped by showing of the 2θ at 23.205, 23.723, 24.384, 33.426, and 33.911. The characterization using Field Emission Scanning Electron Microscopy (FESEM) showed that the material obtained was a disk-shaped with diameter 150–250 nm and a thickness of 50 nm. The Energy Dispersive X-ray spectroscopy (EDX) also confirms WO3 compound with no impurities. The gold electrode was modified by dip immersion technique where the gold electrode was dipped in a mixture of WO3-carbon paste. The measurement of surface area by cyclic voltammetry shows that the WO3/C modified gold electrode has the highest surface area compared to unmodified gold and C-modified gold electrode, indicating it has more active electron transfer sites. The WO3/C modified gold electrode worked well at pH 7 for the detection of nitrite ion and gave the highest peak current (0.875 V) than the others. The measurement ranges from 1–200 mg/L with no interference from NO3−, SO42−, Zn2+, Fe2+, Pb2+, Cl−, Ca2+, and NH4+ ions. The sensitivity and the LOD of the electrode are 8.86 μA.L.mg−1.cm−2 and 0.8 µg/L, respectively. The proposed method not only exhibits identical precision and accuracy to the standard method in detecting nitrite ions in real samples but also offers the advantages of rapid analysis, uncomplicated pretreatment procedures, environmental friendliness, and economical operation. This performance indicates that the WO3/C modified gold electrode is feasible as an alternative electrode for nitrite ion detection.
KW - Fast detection
KW - Nitrite ion
KW - Sensor
KW - Tungsten
UR - http://www.scopus.com/inward/record.url?scp=85196257732&partnerID=8YFLogxK
U2 - 10.1016/j.electacta.2024.144590
DO - 10.1016/j.electacta.2024.144590
M3 - Article
AN - SCOPUS:85196257732
SN - 0013-4686
VL - 497
JO - Electrochimica Acta
JF - Electrochimica Acta
M1 - 144590
ER -