TY - JOUR
T1 - Advancing Non-Cuff Hypertension Detection
T2 - Leveraging 1D Convolutional Neural Network and Time Domain Physiological Signals
AU - Nuryani, Nuryani
AU - Utomo, Trio Pambudi
AU - Prabowo, Nurhasan Agung
AU - Aripriharta,
AU - Yazid, Muhammad
AU - Yunianto, Mohtar
N1 - Publisher Copyright:
© 2024 by the authors of this article.
PY - 2024/3/15
Y1 - 2024/3/15
N2 - Timely identification of hypertension (HT) is crucial for effectively managing and reducing the potential health consequences, including cardiovascular events such as heart attacks and strokes, as well as the development of kidney disease. Traditional cuff-based devices often discourage regular monitoring because they cause discomfort. Furthermore, the lack of symptoms in HT complicates the early detection of this condition. To address these challenges, our study employs a non-cuff methodology that utilizes unprocessed electrocardiogram (ECG) and photoplethysmogram (PPG) signals. We utilize a customized approach to enhance the features of a one-dimensional convolutional neural network (CNN) specifically tailored to optimize timeseries data. In contrast to previous research, our methodology avoids the need for complex signal extraction or transformation techniques. The main goal is to identify the optimal input signals and fine-tune the critical hyperparameters of CNNs. The clinical data underwent analysis, which revealed that the use of an integrated ECG and PPG approach resulted in the highest level of accuracy for detection. Notably, the F1 score achieved an impressive value of 98.88%. When evaluated separately, ECG outperformed PPG. Our study contributes to the advancement of the field by introducing a new approach that combines comfort and high accuracy in the early detection of HT. This method is practical and ensures a patient-friendly experience.
AB - Timely identification of hypertension (HT) is crucial for effectively managing and reducing the potential health consequences, including cardiovascular events such as heart attacks and strokes, as well as the development of kidney disease. Traditional cuff-based devices often discourage regular monitoring because they cause discomfort. Furthermore, the lack of symptoms in HT complicates the early detection of this condition. To address these challenges, our study employs a non-cuff methodology that utilizes unprocessed electrocardiogram (ECG) and photoplethysmogram (PPG) signals. We utilize a customized approach to enhance the features of a one-dimensional convolutional neural network (CNN) specifically tailored to optimize timeseries data. In contrast to previous research, our methodology avoids the need for complex signal extraction or transformation techniques. The main goal is to identify the optimal input signals and fine-tune the critical hyperparameters of CNNs. The clinical data underwent analysis, which revealed that the use of an integrated ECG and PPG approach resulted in the highest level of accuracy for detection. Notably, the F1 score achieved an impressive value of 98.88%. When evaluated separately, ECG outperformed PPG. Our study contributes to the advancement of the field by introducing a new approach that combines comfort and high accuracy in the early detection of HT. This method is practical and ensures a patient-friendly experience.
KW - convolutional neural network (CNN)
KW - electrocardiogram (ECG)
KW - hypertension (HT) detection
KW - non-cuff methods
KW - photoplethysmogram (PPG)
UR - http://www.scopus.com/inward/record.url?scp=85188471068&partnerID=8YFLogxK
U2 - 10.3991/ijoe.v20i05.45547
DO - 10.3991/ijoe.v20i05.45547
M3 - Article
AN - SCOPUS:85188471068
SN - 2626-8493
VL - 20
SP - 78
EP - 100
JO - International journal of online and biomedical engineering
JF - International journal of online and biomedical engineering
IS - 5
ER -