TY - GEN
T1 - Analysis of low voltage arcing characteristic on direct short circuit through arcing thermal synchronization sensing and short circuit current
AU - Asfani, Dimas Anton
AU - Negara, I. Made Yulistya
AU - Fahmi, Daniar
AU - Wiryatama, Rifki
AU - Haq, Muhammad Wildan Arinal
AU - Wahyudi, Mochammad
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/11/28
Y1 - 2017/11/28
N2 - Short circuit fault cause arcing fault initiate fire accident. Fire case caused by short circuit fault in low voltage installation is occured every year. Several cases in fire accident at low voltage installation caused by short circuit fault. In this case, protection equipment failed to detect and secure the installation. This experiment investigate short circuit case at low voltage filament conductor cable 1.5 mm2. Short circuit cases variated by filament or strand that experienced contact. When short circuit occurred, arcing is recorded by thermal camera. Moreover, current and voltage arcing will be synchronized with thermal arcing image. The synchronization result is analyzed to obtain the caharacteristics of arcing that consist of value of maximum temperature arcing, sectional area arcing data, and duration of arcing. These characteristics are very useful to design arcing fault detector. The result shows that the arcing temperature, area, and duration respectively are up to 100 0C, 1300 mm2, 10 seconds.
AB - Short circuit fault cause arcing fault initiate fire accident. Fire case caused by short circuit fault in low voltage installation is occured every year. Several cases in fire accident at low voltage installation caused by short circuit fault. In this case, protection equipment failed to detect and secure the installation. This experiment investigate short circuit case at low voltage filament conductor cable 1.5 mm2. Short circuit cases variated by filament or strand that experienced contact. When short circuit occurred, arcing is recorded by thermal camera. Moreover, current and voltage arcing will be synchronized with thermal arcing image. The synchronization result is analyzed to obtain the caharacteristics of arcing that consist of value of maximum temperature arcing, sectional area arcing data, and duration of arcing. These characteristics are very useful to design arcing fault detector. The result shows that the arcing temperature, area, and duration respectively are up to 100 0C, 1300 mm2, 10 seconds.
KW - Arcing
KW - Arcing characteristic
KW - Low voltage
KW - Thermal camera
UR - https://www.scopus.com/pages/publications/85043599324
U2 - 10.1109/ISITIA.2017.8124074
DO - 10.1109/ISITIA.2017.8124074
M3 - Conference contribution
AN - SCOPUS:85043599324
T3 - 2017 International Seminar on Intelligent Technology and Its Application: Strengthening the Link Between University Research and Industry to Support ASEAN Energy Sector, ISITIA 2017 - Proceeding
SP - 165
EP - 168
BT - 2017 International Seminar on Intelligent Technology and Its Application
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 18th International Seminar on Intelligent Technology and Its Application, ISITIA 2017
Y2 - 28 August 2017 through 29 August 2017
ER -