TY - JOUR
T1 - Bio-mechanical assessment toward throwing and lifting process of i-LOCA (Innovative Lobster Catcher)
AU - Sudiarno, A.
AU - Dewi, D. S.
AU - Putri, M. A.
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2018/4/10
Y1 - 2018/4/10
N2 - Indonesia is the country rich in marine resource, one of which is lobster. East java, one of Indonesian province, especially in Region of Gresik and Lamogan, has very huge potential of lobster. Current condition shown that lobster catch by the fisherman mostly depend on lucky factor, which the lobster unintentionally trapped in fisherman's fish net. By using this mechanism, the number of lobster catch cannot be optimum. Previous researches have produced two versions of i-LOCA, Innovative Lobster Catcher, a special tool for catching the lobster. Although produce more lobster catch, second version of i-LOCA still needs to be scrutinized, one of that is bio-mechanical assessment. The second version of i-LOCA still has no tool to ease throwing and lifting it into the sea. This condition cause Musculoskeletal Disorder (MSD) toward the fisherman. This research perform bio-mechanical assessment toward throwing and lifting process in order to suggest improvement for i-LOCA as the third version. Based on body moment calculation, we found that throwing and lifting process of third version of i-LOCA, each was 3 times and 2 times better than second version of i-LOCA. Meanwhile, Rapid Entire Body Assessment (REBA) score of throwing and lifting process for third version of i-LOCA can be reduced by 5 points compared to second version of i-LOCA.
AB - Indonesia is the country rich in marine resource, one of which is lobster. East java, one of Indonesian province, especially in Region of Gresik and Lamogan, has very huge potential of lobster. Current condition shown that lobster catch by the fisherman mostly depend on lucky factor, which the lobster unintentionally trapped in fisherman's fish net. By using this mechanism, the number of lobster catch cannot be optimum. Previous researches have produced two versions of i-LOCA, Innovative Lobster Catcher, a special tool for catching the lobster. Although produce more lobster catch, second version of i-LOCA still needs to be scrutinized, one of that is bio-mechanical assessment. The second version of i-LOCA still has no tool to ease throwing and lifting it into the sea. This condition cause Musculoskeletal Disorder (MSD) toward the fisherman. This research perform bio-mechanical assessment toward throwing and lifting process in order to suggest improvement for i-LOCA as the third version. Based on body moment calculation, we found that throwing and lifting process of third version of i-LOCA, each was 3 times and 2 times better than second version of i-LOCA. Meanwhile, Rapid Entire Body Assessment (REBA) score of throwing and lifting process for third version of i-LOCA can be reduced by 5 points compared to second version of i-LOCA.
UR - http://www.scopus.com/inward/record.url?scp=85046256446&partnerID=8YFLogxK
U2 - 10.1088/1757-899X/337/1/012040
DO - 10.1088/1757-899X/337/1/012040
M3 - Conference article
AN - SCOPUS:85046256446
SN - 1757-8981
VL - 337
JO - IOP Conference Series: Materials Science and Engineering
JF - IOP Conference Series: Materials Science and Engineering
IS - 1
M1 - 012040
T2 - 1st International Conference on Industrial and Systems Engineering, IConISE 2017
Y2 - 29 August 2017 through 30 August 2017
ER -