Abstract

Early detection of incipient fault is highly necessary for condition assessment, predictive maintenance and reliability operation of induction motors. For this task, motor current signature analysis based on frequency characteristic is well-utilized to detect indicants of permanently short circuit condition. This paper characterizes the current behavior of induction motor under temporary short circuit located in stator winding using wavelet transform. The non periodic, very short duration and high impedance short circuit currents in induction motor can be effectively identified using magnitude and energy of high frequency signal based wavelet transform.

Original languageEnglish
Title of host publication2010 International Conference on Modelling, Identification and Control, ICMIC 2010
Pages477-482
Number of pages6
Publication statusPublished - 2010
Event2010 International Conference on Modelling, Identification and Control, ICMIC 2010 - Okayama, Japan
Duration: 17 Jul 201019 Jul 2010

Publication series

Name2010 International Conference on Modelling, Identification and Control, ICMIC 2010

Conference

Conference2010 International Conference on Modelling, Identification and Control, ICMIC 2010
Country/TerritoryJapan
CityOkayama
Period17/07/1019/07/10

Keywords

  • Early detection
  • Induction motor
  • Temporary fault
  • Wavelet transform

Fingerprint

Dive into the research topics of 'Characterization of temporary short circuit in induction motor winding using wavelet analysis'. Together they form a unique fingerprint.