Hypertension, a primary cause of cardiovascular diseases (CVD), necessitates real-time and continuous blood pressure (BP) monitoring for accurate diagnosis and treatment. However, existing methods for continuous BP measurement are often invasive and painful, while non-invasive methods using cuffs lack convenience for continuous monitoring. This study proposes a continuous, non-invasive cuffless BP detection method using electrocardiogram (ECG) and photoplethysmogram (PPG) signals. By applying an Artificial Neural Network (ANN), we achieved accurate estimations of systolic (SBP) and diastolic (DBP) blood pressure. The model, developed with the MIMIC II database, demonstrated a Mean Absolute Error (MAE) of ±13.89 mmHg for SBP and ±5.5 mmHg for DBP. Comparisons with conventional methods showed an average error of 11.2 mmHg for SBP and 9.75 mmHg for DBP, validating its effectiveness for noninvasive, continuous BP monitoring without causing pain or risk of injury.

Original languageEnglish
Title of host publicationProceedings of the International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2024
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9798350368802
DOIs
Publication statusPublished - 2024
Event2024 International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2024 - Hybrid, Surabaya, Indonesia
Duration: 19 Nov 2024 → 20 Nov 2024

Publication series

NameProceedings of the International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2024

Conference

Conference2024 International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2024
Country/TerritoryIndonesia
CityHybrid, Surabaya
Period19/11/24 → 20/11/24

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • ANN
  • Blood Pressure
  • ECG
  • PPG

Fingerprint

Dive into the research topics of 'Continuous Cuffless Non-Invasive Blood Pressure Detection from ECG and PPG Signals Using Artificial Neural Network'. Together they form a unique fingerprint.

Cite this