N2 - BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.
AB - BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.
KW - BLDC Motor
KW - EAR
KW - Isolation Failure
KW - Short Circuit
KW - Surge Test
UR - http://www.scopus.com/inward/record.url?scp=85091706136&partnerID=8YFLogxK
U2 - 10.1109/ISITIA49792.2020.9163679
DO - 10.1109/ISITIA49792.2020.9163679
M3 - Conference contribution
AN - SCOPUS:85091706136
T3 - Proceedings - 2020 International Seminar on Intelligent Technology and Its Application: Humanification of Reliable Intelligent Systems, ISITIA 2020
SP - 398
EP - 404
BT - Proceedings - 2020 International Seminar on Intelligent Technology and Its Application
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2020 International Seminar on Intelligent Technology and Its Application, ISITIA 2020
Y2 - 22 July 2020 through 23 July 2020
ER -