T1 - Development of a Chromium (VI) Biosensor Using Silver-Modifified Milkfifish (Chanos chanos) Gelatin and Carbon Electrodes
AU - Hutapea, Tri P.Hasiholan
AU - Muliyadi, Muliyadi
AU - Rukisah, Rukisah
AU - Suprapto, Suprapto
AU - Kurniawan, Fredy
N1 - Publisher Copyright:
© (2024), (L.N. Gumilyov Eurasian National University). All rights reserved.
PY - 2024
Y1 - 2024
N2 - Detection of chromium (VI) metal ions using fish gelatin-based electrodes and silver-modified carbon electrodes (FGC-AgE) has been successfully developed. Chromium (VI) is a toxic heavy metal commonly found in contaminated water sources and poses significant risks to human health and the environment. Therefore, monitoring and control of Cr (VI) are very important. The purpose of this study was to develop a sensitive and selective electrochemical sensor for detecting Cr (VI) in water. The research stages include: (1) extraction of fish gelatin, (2) fabrication of FGC-AgE working electrodes, and (3) analysis of electrode performance. The tests include optimization of pH, concentration effects, selectivity to other ions, and repeatability tests. All analyses were carried out using the cyclic voltammetry method in the potential range of –1000 mV to +1000 mV with a scanning rate of 100 mV/s. The results showed that FGC-AgE worked optimally under alkaline conditions, with the highest current response at a potential of –0.249 V. This electrode has a measuring range of 1–7 µM, a detection limit of 0.295 µM and a sensitivity of 14.32 µA. µM–1.µm–2. In addition, FGC-AgE showed high selectivity towards Cr (VI) and was not affected by the presence of other metal ions such as iron, cadmium, lead, copper, and chromium (III). Repeated tests showed consistent electrode performance. In summary, FGC-AgE electrode has the potential to be an effective and reliable alternative for detecting Cr (VI) ions in the future.
AB - Detection of chromium (VI) metal ions using fish gelatin-based electrodes and silver-modified carbon electrodes (FGC-AgE) has been successfully developed. Chromium (VI) is a toxic heavy metal commonly found in contaminated water sources and poses significant risks to human health and the environment. Therefore, monitoring and control of Cr (VI) are very important. The purpose of this study was to develop a sensitive and selective electrochemical sensor for detecting Cr (VI) in water. The research stages include: (1) extraction of fish gelatin, (2) fabrication of FGC-AgE working electrodes, and (3) analysis of electrode performance. The tests include optimization of pH, concentration effects, selectivity to other ions, and repeatability tests. All analyses were carried out using the cyclic voltammetry method in the potential range of –1000 mV to +1000 mV with a scanning rate of 100 mV/s. The results showed that FGC-AgE worked optimally under alkaline conditions, with the highest current response at a potential of –0.249 V. This electrode has a measuring range of 1–7 µM, a detection limit of 0.295 µM and a sensitivity of 14.32 µA. µM–1.µm–2. In addition, FGC-AgE showed high selectivity towards Cr (VI) and was not affected by the presence of other metal ions such as iron, cadmium, lead, copper, and chromium (III). Repeated tests showed consistent electrode performance. In summary, FGC-AgE electrode has the potential to be an effective and reliable alternative for detecting Cr (VI) ions in the future.
KW - Carbon
KW - Chromium (VI)
KW - Cyclic voltammetry
KW - Fish gelatin
UR - http://www.scopus.com/inward/record.url?scp=85214691650&partnerID=8YFLogxK
U2 - 10.69912/2616-8537.1234
DO - 10.69912/2616-8537.1234
M3 - Article
AN - SCOPUS:85214691650
SN - 2522-9869
VL - 8
SP - 178
EP - 184
JO - Eurasian Journal of Physics and Functional Materials
JF - Eurasian Journal of Physics and Functional Materials
IS - 4
ER -