T1 - Development of a Compact Optical Measurement System for Non-Invasive Blood Glucose Screening
AU - M, Yeti
AU - Patrialova, Sefi N.
AU - Rulloh, Rafly Z.
AU - Husain, Muhammad Z.A.F.
AU - R, Rahadiyan
AU - Segar, Yus P.A.
AU - Pratama, I. Putu E.W.
AU - A, Shofuro
AU - P, Brian
AU - Liaw, Shien K.
AU - Raditya, Murry
AU - Adziimaa, Ahmad F.
N1 - Publisher Copyright:
© 2026, Published under licence by IOP Publishing Ltd. Content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
PY - 2026
Y1 - 2026
N2 - Conventional glucose monitoring such as finger pricking is invasive and often reduces patient adherence due to pain and discomfort. Non-invasive approaches using near infrared light offer a promising alternative. This article presents a novel, low-cost, and portable non-invasive glucose monitoring device utilizing a 950 nm NIR LED and photodiode sensor system. Changes in optical intensity through fingertip tissue were converted into voltage signals and processed by an ESP32 microcontroller with an integrated display. The prototype was evaluated on human volunteers and benchmarked against a commercial glucometer. Across 15 participants, each measured 10 times, the system achieved an overall accuracy of 82,13%. Clarke Error Grid analysis showed that most predictions fell within Zone C, indicating limited clinical reliability. It demonstrates potential for preliminary screening and glucose trend monitoring. These findings highlight both the feasibility of a low-cost optical approach and the need for further optimization to achieve clinically acceptable accuracy.
AB - Conventional glucose monitoring such as finger pricking is invasive and often reduces patient adherence due to pain and discomfort. Non-invasive approaches using near infrared light offer a promising alternative. This article presents a novel, low-cost, and portable non-invasive glucose monitoring device utilizing a 950 nm NIR LED and photodiode sensor system. Changes in optical intensity through fingertip tissue were converted into voltage signals and processed by an ESP32 microcontroller with an integrated display. The prototype was evaluated on human volunteers and benchmarked against a commercial glucometer. Across 15 participants, each measured 10 times, the system achieved an overall accuracy of 82,13%. Clarke Error Grid analysis showed that most predictions fell within Zone C, indicating limited clinical reliability. It demonstrates potential for preliminary screening and glucose trend monitoring. These findings highlight both the feasibility of a low-cost optical approach and the need for further optimization to achieve clinically acceptable accuracy.
UR - https://www.scopus.com/pages/publications/105052311052
U2 - 10.1088/1742-6596/3210/1/012010
DO - 10.1088/1742-6596/3210/1/012010
M3 - Conference article
AN - SCOPUS:105052311052
SN - 1742-6588
VL - 3210
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012010
T2 - 15th International Symposium on Modern Optics and Its Applications, ISMOA 2025
Y2 - 28 July 2025 through 31 July 2025
ER -