TY - GEN
T1 - Dialysate Fluid Flow Control System in Balancing Chamber in Ultrafiltration Process in Hemodialysis
AU - Permatasari, Febrianti
AU - Sardjono, Tri Arief
AU - Fatoni, Muhammad Hilman
N1 - Publisher Copyright:
© 2022 IEEE.
PY - 2022
Y1 - 2022
N2 - The Indonesian Renal Registry (IRR) states that in 2015 there were 30,554 active dialysis patients with Chronic Kidney Disease (CKD) which is a failure of kidney function to maintain metabolism, fluid and electrolyte balance. In the dialysis process, there is a necessary process called ultrafiltration which uses negative pressure dialysate, which is regulated by using a pump to control the flow rate of the dialysate. This study aimed to develop a method of controlling the flow of dialysate fluid in the ultrafiltration process on a hemodialysis machine. A fuzzy logic controller is used in the system to control the pump based on the flow sensor feedback, and there is also a valve opening and closing mechanism in the chamber using a timer that is adjusted every cycle. The results of a dialysate flow control system using fuzzy logic controller as a pump controller produce an oscillating flow rate at the set point and following the desired range between 300 - 600ml/min, with an error of 2.4%. Moreover, the opening and closing valve mechanism has an accuracy rate of time to work for one cycle with the average Error of 2.075%
AB - The Indonesian Renal Registry (IRR) states that in 2015 there were 30,554 active dialysis patients with Chronic Kidney Disease (CKD) which is a failure of kidney function to maintain metabolism, fluid and electrolyte balance. In the dialysis process, there is a necessary process called ultrafiltration which uses negative pressure dialysate, which is regulated by using a pump to control the flow rate of the dialysate. This study aimed to develop a method of controlling the flow of dialysate fluid in the ultrafiltration process on a hemodialysis machine. A fuzzy logic controller is used in the system to control the pump based on the flow sensor feedback, and there is also a valve opening and closing mechanism in the chamber using a timer that is adjusted every cycle. The results of a dialysate flow control system using fuzzy logic controller as a pump controller produce an oscillating flow rate at the set point and following the desired range between 300 - 600ml/min, with an error of 2.4%. Moreover, the opening and closing valve mechanism has an accuracy rate of time to work for one cycle with the average Error of 2.075%
KW - Balancing Chamber
KW - Dialysate Fluid
KW - Fuzzy Logic Controller
KW - Hemodialysis
KW - Kidney
KW - Ultrafiltration
UR - http://www.scopus.com/inward/record.url?scp=85148622540&partnerID=8YFLogxK
U2 - 10.1109/ICICyTA57421.2022.10038150
DO - 10.1109/ICICyTA57421.2022.10038150
M3 - Conference contribution
AN - SCOPUS:85148622540
T3 - 2022 2nd International Conference on Intelligent Cybernetics Technology and Applications, ICICyTA 2022
SP - 272
EP - 277
BT - 2022 2nd International Conference on Intelligent Cybernetics Technology and Applications, ICICyTA 2022
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2nd International Conference on Intelligent Cybernetics Technology and Applications, ICICyTA 2022
Y2 - 15 December 2022 through 16 December 2022
ER -