T1 - Effect of air conditioning position on thermal comfort in the floor air conditioning system
AU - Sabtalistia, Y. A.
AU - Ekasiwi, S. N.N.
AU - Iskandriawan, B.
PY - 2014
Y1 - 2014
N2 - Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too. This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation. This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.
AB - Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too. This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation. This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.
KW - Air Diffusion Performance Index (ADPI)
KW - Apartment
KW - Draft Risk (DR)
KW - Floor Air Conditioning (FAC)
KW - Thermal comfort
UR - http://www.scopus.com/inward/record.url?scp=84892847819&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMM.493.74
DO - 10.4028/www.scientific.net/AMM.493.74
M3 - Conference contribution
AN - SCOPUS:84892847819
SN - 9783037859902
T3 - Applied Mechanics and Materials
SP - 74
EP - 79
BT - Advances in Applied Mechanics and Materials
T2 - International Conference on Mechanical Engineering, ICOME 2013
Y2 - 19 September 2013 through 21 September 2013
ER -