Skip to main navigation Skip to search Skip to main content

Effect of cone-beam computed tomography voxel size on detection of vertical periodontal bone defects

  • Nina Rouzmeh
  • , Masoumeh Eftekhar*
  • , Hanieh Kaviani
  • , Alireza Akbarzadeh Baghban
  • *Corresponding author for this work
  • Tehran University of Medical Sciences
  • Shahid Beheshti University of Medical Sciences

Research output: Contribution to journalReview articlepeer-review

Abstract

Objectives: Finding the best voxel size for the detection of vertical periodontal bone defects with minimum patient radiation dose is a priority. This study sought to assess the effect of cone-beam computed tomography (CBCT) voxel size on the detection of vertical bone de-fects. Materials and Methods: In this in vitro, experimental study, 31 vertical defects including 2 one-wall, 12 two-wall, and 17 three-wall defects were randomly created in the maxilla and mandible of four sheep skulls with the associated soft tissue using round and needle burs. Forty sound sites were considered as the control group. The CBCT scans were obtained from the skulls with 0.150 and 0.300 mm3 vox-el sizes and 8 x 11 cm2 field of view (FOV). The images were randomly evaluated by two oral and maxillofacial radiologists and two peri-odontists, and their findings were recorded. The inter-rater observer agreement (weighted kappa), sensitivity and specificity values were calculated for each voxel size. Comparisons were made using paired t-test. Results: The two voxel sizes had no signifi-cant difference in detecting one-wall and two-wall defects (P>0.05). But the smaller voxel size was significantly superior for detecting three-wall defects (P=0.001). The inter-rater observer agreement was unfavorable (kappa < 0.6) for the detection of all three defect types. Conclusion: In general, increasing the image resolution by decreasing the voxel size in-creased the sensitivity and reduced the specificity of CBCT for detection of vertical bone defects, and is only recommended for detection of three-wall defects.

Original languageEnglish
Pages (from-to)3-11
Number of pages9
JournalORAL and Implantology
Volume15
Issue number1
Publication statusPublished - 2022
Externally publishedYes

Keywords

  • Cone-Beam Computed Tomog-raphy
  • Resolution
  • Vertical Bone Defects
  • Vox-el Size

Fingerprint

Dive into the research topics of 'Effect of cone-beam computed tomography voxel size on detection of vertical periodontal bone defects'. Together they form a unique fingerprint.

Cite this