Electrical and electrochemical pH sensing technologies: comparative mechanisms, performance, and applications

  • Saroja Rijal
  • , Uda Hashim*
  • , M. N.Afnan Uda
  • , M. N.A. Uda
  • , Yuri Pamungkas
  • *Corresponding author for this work
  • Faculty of Engineering
  • Universiti Malaysia Sabah
  • Faculty of Mechanical Engineering & Technology
  • Universiti Malaysia Perlis

Research output: Contribution to journal › Article › peer-review

2 Citations (Scopus)

Abstract

Reliable pH measurement remains central to chemical, biological, and environmental monitoring, yet conventional electrochemical glass electrodes face persistent challenges of fragility, slow response, and limited integrability. This study presents a comparative analysis between a conventional glass-electrode pH meter and a custom-fabricated aluminum interdigitated electrode (Al-IDE) for full-range pH sensing (pH 1–13). The Al-IDE device, fabricated via standard photolithography on thermally oxidized silicon, was evaluated under identical conditions using pure buffer systems. Electrical measurements revealed a distinct U-shaped current response, decreasing from 3107 nA at pH 1 to 1.03 nA near pH 7, before rising to 781 nA at pH 13. This behaviour reflects the amphoteric nature of the Al₂O₃ surface, governed by protonation–deprotonation equilibria that modulate interfacial charge transport. The proposed nonlinear quadratic model achieved strong segmental correlations (R² > 0.89) for both acidic and alkaline regimes. Comparative assessment against the glass electrode yielded a mean absolute deviation of ≈ 0.19 pH units, confirming excellent agreement between the two modalities. While the glass electrode followed a linear Nernstian slope (–58.6 mV pH⁻¹), the Al-IDE offered rapid, reference-free, and mechanically robust operation with repeatability (RSD) ranging up to 3.5%. These findings establish the Al-IDE as a low-cost, CMOS-compatible alternative for portable or embedded pH monitoring and provide foundational insights for hybrid electro-electrical sensing architectures that integrate the precision of electrochemical systems with the real-time responsiveness of electrical transduction.

Original languageEnglish
Pages (from-to)1869-1878
Number of pages10
JournalJournal of Solid State Electrochemistry
Volume30
Issue number5
DOIs
Publication statusPublished - May 2026

Keywords

  • Conductivity
  • Electrical pH sensor
  • Electrochemical pH sensor
  • Interdigitated electrode (IDE)
  • PH monitoring
  • Sensor comparison

Fingerprint

Dive into the research topics of 'Electrical and electrochemical pH sensing technologies: comparative mechanisms, performance, and applications'. Together they form a unique fingerprint.