TY - JOUR
T1 - Electrochemical and Optical Analysis of Various Compositions of Au and Ag Layers for Blood Cancer Prognosis
AU - Farahdina, Ulya
AU - Muliawati, Amastasia Salsabila
AU - Zulfa, Vinda Zakiyatuz
AU - Firdhaus, Miftakhul
AU - Aziz, Ihwanul
AU - Suprihatin, Hari
AU - Darsono, Darsono
AU - Nasori, Nasori
AU - Rubiyanto, Agus
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/1
Y1 - 2023/1
N2 - The fabrication of silver (Ag) and gold (Au) thin film electrodes was successfully carried out using the DC sputtering deposition method. These thin film electrodes were able to detect the increase in serum albumin concentration that was used as a prognostic factor for leukemia. The simulation and the optical experimental analysis show that an increase in BSA concentration can increase the absorbance peak observed at a wavelength of 435 nm on hypoalbumin medium and 470 nm on normal concentration of serum albumin medium. The performance of the electrodes was electrochemically tested, in which it was shown that a decrease in oxidation and reduction peaks occurred with respect to an increase in BSA concentration. An oxidation peak was observed at a voltage of 0.5 V for the Ag thin film. For the Au, Au/Ag, and Ag/Au thin films, an oxidation peak was observed at a voltage of 1.0 V. The limits of detection (LODs) of the Ag, Ag/Au, Au, and Au/Ag thin films were 0.56, 0.24, 0.64, and 0.36 g/dL, respectively. Therefore, based on both the electrochemical and optical analysis, the Ag/Au thin film possessed the highest potential for prognosis monitoring of leukemia compared with the other Ag and Au thin films.
AB - The fabrication of silver (Ag) and gold (Au) thin film electrodes was successfully carried out using the DC sputtering deposition method. These thin film electrodes were able to detect the increase in serum albumin concentration that was used as a prognostic factor for leukemia. The simulation and the optical experimental analysis show that an increase in BSA concentration can increase the absorbance peak observed at a wavelength of 435 nm on hypoalbumin medium and 470 nm on normal concentration of serum albumin medium. The performance of the electrodes was electrochemically tested, in which it was shown that a decrease in oxidation and reduction peaks occurred with respect to an increase in BSA concentration. An oxidation peak was observed at a voltage of 0.5 V for the Ag thin film. For the Au, Au/Ag, and Ag/Au thin films, an oxidation peak was observed at a voltage of 1.0 V. The limits of detection (LODs) of the Ag, Ag/Au, Au, and Au/Ag thin films were 0.56, 0.24, 0.64, and 0.36 g/dL, respectively. Therefore, based on both the electrochemical and optical analysis, the Ag/Au thin film possessed the highest potential for prognosis monitoring of leukemia compared with the other Ag and Au thin films.
KW - electrochemistry
KW - leukemia
KW - optic
KW - prognosis
KW - thin film
UR - http://www.scopus.com/inward/record.url?scp=85146787416&partnerID=8YFLogxK
U2 - 10.3390/coatings13010186
DO - 10.3390/coatings13010186
M3 - Article
AN - SCOPUS:85146787416
SN - 2079-6412
VL - 13
JO - Coatings
JF - Coatings
IS - 1
M1 - 186
ER -