N2 - The acoustic performance of open-plan office has become an important topic for discussion along with the development of office centers in major cities in Indonesia, including in Surabaya. Acoustic problems at open plan office often arise, such as background noise and speech privacy. Based on ISO 3382-3 2012, an open plan office must meet certain standards to keep productivity and concentration. These parameters are Average A-Weighted Background Noise (Lp, A, B), A-Weighted SPL of Speech at 4 m (Lp, A, s, 4m), Spatial Decay Rate of A-Weighted SPL of Speech (D2,s), Distraction Distance (rD), Privacy Distance (rP). From measurement and calculation did to an office building in Surabaya obtained a value of Lp, A, B equal to 52 dBA, Lp, A, s, 4m 52 dBA, D2, S 4,19 dBA, rD 11,75 m, rP 23, 8 m, and STI at the nearest table 0.78. These results indicate that further acoustic treatment is required to meet the standards specified by ISO.
AB - The acoustic performance of open-plan office has become an important topic for discussion along with the development of office centers in major cities in Indonesia, including in Surabaya. Acoustic problems at open plan office often arise, such as background noise and speech privacy. Based on ISO 3382-3 2012, an open plan office must meet certain standards to keep productivity and concentration. These parameters are Average A-Weighted Background Noise (Lp, A, B), A-Weighted SPL of Speech at 4 m (Lp, A, s, 4m), Spatial Decay Rate of A-Weighted SPL of Speech (D2,s), Distraction Distance (rD), Privacy Distance (rP). From measurement and calculation did to an office building in Surabaya obtained a value of Lp, A, B equal to 52 dBA, Lp, A, s, 4m 52 dBA, D2, S 4,19 dBA, rD 11,75 m, rP 23, 8 m, and STI at the nearest table 0.78. These results indicate that further acoustic treatment is required to meet the standards specified by ISO.
UR - http://www.scopus.com/inward/record.url?scp=85056470103&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/1075/1/012050
DO - 10.1088/1742-6596/1075/1/012050
M3 - Conference article
AN - SCOPUS:85056470103
SN - 1742-6588
VL - 1075
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012050
T2 - Regional Conference on Acoustics and Vibration 2017, RECAV 2017
Y2 - 27 November 2017 through 28 November 2017
ER -