TY - JOUR
T1 - Fabrication of Mixed Matrix Membrane Polysulfone-Zeolite Carbon Composites (ZCC) for Gas Separation
AU - Larasati, Z. S.
AU - Wijiyanti, R.
AU - Karim, Z. A.
AU - Ismail, A. F.
AU - Widiastuti, N.
N1 - Publisher Copyright:
© 2019 IOP Publishing Ltd. All rights reserved.
PY - 2019/7/1
Y1 - 2019/7/1
N2 - Mixed matrix membrane polysulfone (PSF)-zeolite carbon composite (ZCC) was successfully fabricated in this study. The composition of ZCC as a filler in this membrane was 1%. Mixed matrix membrane PSF-ZCC 1 wt% was compared by neat polysulfone membrane. The prepared membranes were characterized using XRD to determine the membrane structure and FTIR to determine the functional groups in the membrane. The results of gas permeation for membrane permeability of O2 were 4.011 and 7.193 GPU for neat PSF and PSF-ZCC 1 wt% membrane, respectively. In addition, the permeability value of N2 was 5.603 and 7.862 GPU for neat PSF and PSF-ZCC 1 wt% membrane, respectively. Selectivities of O2/N2 for neat PSF and PSF-ZCC 1 wt% membrane were 0.715 and 0.914, respectively. The increasing permeability along with the addition of ZCC filler indicated that the membrane in this study is potentially applied for O2 and N2 separation.
AB - Mixed matrix membrane polysulfone (PSF)-zeolite carbon composite (ZCC) was successfully fabricated in this study. The composition of ZCC as a filler in this membrane was 1%. Mixed matrix membrane PSF-ZCC 1 wt% was compared by neat polysulfone membrane. The prepared membranes were characterized using XRD to determine the membrane structure and FTIR to determine the functional groups in the membrane. The results of gas permeation for membrane permeability of O2 were 4.011 and 7.193 GPU for neat PSF and PSF-ZCC 1 wt% membrane, respectively. In addition, the permeability value of N2 was 5.603 and 7.862 GPU for neat PSF and PSF-ZCC 1 wt% membrane, respectively. Selectivities of O2/N2 for neat PSF and PSF-ZCC 1 wt% membrane were 0.715 and 0.914, respectively. The increasing permeability along with the addition of ZCC filler indicated that the membrane in this study is potentially applied for O2 and N2 separation.
UR - http://www.scopus.com/inward/record.url?scp=85069206420&partnerID=8YFLogxK
U2 - 10.1088/1757-899X/546/4/042020
DO - 10.1088/1757-899X/546/4/042020
M3 - Conference article
AN - SCOPUS:85069206420
SN - 1757-8981
VL - 546
JO - IOP Conference Series: Materials Science and Engineering
JF - IOP Conference Series: Materials Science and Engineering
IS - 4
M1 - 042020
T2 - 9th Annual Basic Science International Conference 2019, BaSIC 2019
Y2 - 20 March 2019 through 21 March 2019
ER -