TY - GEN
T1 - Fabrication of Porous Mg–Ca–Zn Alloy by High Energy Milling for Bone Implants
AU - Kartika, Ika
AU - Risanti, Doty Dewi
AU - Laksana, Hardhian Restu P.
AU - Lestari, Franciska Pramuji
AU - Rokhmanto, Fendy
AU - Erryani, Aprilia
N1 - Publisher Copyright:
© 2021, The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
PY - 2021
Y1 - 2021
N2 - Biodegradable porous magnesium-based alloys are essential in hard tissue engineering, such as mechanical support during healing process, and disappear after completion of the healing process, avoiding the secondary surgery. The present study aims to fabricate Mg–Ca–Zn degradable metallic foam implant for domestically made bone replacement. The foam was introduced through the variation of TiH2 addition as blowing agent that will create a large volume fraction of gas-filled pores during heating. A High-Energy-Milling (HEM) was performed by a horizontal rotating cylinder ball mill with a rotation speed of 130 rpm for 48 h, with the ratio of metallic powders: balls are 3:7 followed by a compacting process. Some samples were subjected to preheating at 450 °C for 2 h before sintering process to observe its effect on pore formation of the green compact, followed by sintering at the temperature of 550 and 650 °C for 3 h. Samples sintered at 650 °C showed profuse micro-cracks, due to uncontrollable release of H2 gas in the liquid film creating pore rupture and MgO formation that detected from XRD analysis, that impedes the sintering process. While sintering at a lower temperature showed a dependence on preheating process. The preheated samples containing MgO suffered from micro-cracking, except for sample with 3 wt% of TiH2, where TiH2 can act as oxygen scavenger that hinders the formation of MgO. In contrast, all samples without preheating remained intact without obvious micro-cracks. Those samples have a comparable hardness value to that of the bone. The pores in the materials measured according to Archimedes procedure behave as gypsum. Thus concerning mechanical properties, the samples can be regarded as bone implants.
AB - Biodegradable porous magnesium-based alloys are essential in hard tissue engineering, such as mechanical support during healing process, and disappear after completion of the healing process, avoiding the secondary surgery. The present study aims to fabricate Mg–Ca–Zn degradable metallic foam implant for domestically made bone replacement. The foam was introduced through the variation of TiH2 addition as blowing agent that will create a large volume fraction of gas-filled pores during heating. A High-Energy-Milling (HEM) was performed by a horizontal rotating cylinder ball mill with a rotation speed of 130 rpm for 48 h, with the ratio of metallic powders: balls are 3:7 followed by a compacting process. Some samples were subjected to preheating at 450 °C for 2 h before sintering process to observe its effect on pore formation of the green compact, followed by sintering at the temperature of 550 and 650 °C for 3 h. Samples sintered at 650 °C showed profuse micro-cracks, due to uncontrollable release of H2 gas in the liquid film creating pore rupture and MgO formation that detected from XRD analysis, that impedes the sintering process. While sintering at a lower temperature showed a dependence on preheating process. The preheated samples containing MgO suffered from micro-cracking, except for sample with 3 wt% of TiH2, where TiH2 can act as oxygen scavenger that hinders the formation of MgO. In contrast, all samples without preheating remained intact without obvious micro-cracks. Those samples have a comparable hardness value to that of the bone. The pores in the materials measured according to Archimedes procedure behave as gypsum. Thus concerning mechanical properties, the samples can be regarded as bone implants.
KW - Blowing agent
KW - Metal foam
KW - Mg–Ca–Zn alloy
UR - http://www.scopus.com/inward/record.url?scp=85105947275&partnerID=8YFLogxK
U2 - 10.1007/978-981-33-6926-9_62
DO - 10.1007/978-981-33-6926-9_62
M3 - Conference contribution
AN - SCOPUS:85105947275
SN - 9789813369252
T3 - Lecture Notes in Electrical Engineering
SP - 711
EP - 722
BT - Proceedings of the 1st International Conference on Electronics, Biomedical Engineering, and Health Informatics - ICEBEHI 2020
A2 - Triwiyanto, T.
A2 - Nugroho, Hanung Adi
A2 - Rizal, Achmad
A2 - Caesarendra, Wahyu
PB - Springer Science and Business Media Deutschland GmbH
T2 - 1st International Conference on Electronics, Biomedical Engineering, and Health Informatics, ICEBEHI 2020
Y2 - 8 October 2020 through 9 October 2020
ER -