TY - GEN
T1 - Hybrid Fuzzy C-Means (FCM) and Active Contour Method for Melanoma Segmentation
AU - Rismawan, Yudha Andriano
AU - Iriawan, Nur
AU - Fithriasari, Kartika
N1 - Publisher Copyright:
© 2026 IEEE.
PY - 2026
Y1 - 2026
N2 - Melanoma segmentation from dermoscopic images is challenging due to fuzzy boundaries, low contrast, and visual artifacts. This study aims to develop a robust segmentation method that improves sensitivity to such conditions. The proposed approach integrates Fuzzy C-Means (FCM) clustering with Active Contour (Chan-Vese) refinement, enhanced by an area constraint and a gradient-based boundary selection mechanism. The procedure includes preprocessing (hair removal, illumination correction, and adaptive vignette-free region extraction), followed by FCM initialization and contour refinement. Experimental results demonstrate that the proposed method outperforms the Otsu baseline, achieving higher intra-region uniformity (0.368 vs. 0.363) and inter-region contrast (0.999 vs. 0.997), resulting in a better overall quality score (0.3675 vs. 0.3609). These findings indicate that the method produces more accurate and stable lesion segmentation. The proposed framework offers a practical solution for melanoma segmentation, particularly in scenarios where ground-truth annotations are limited.
AB - Melanoma segmentation from dermoscopic images is challenging due to fuzzy boundaries, low contrast, and visual artifacts. This study aims to develop a robust segmentation method that improves sensitivity to such conditions. The proposed approach integrates Fuzzy C-Means (FCM) clustering with Active Contour (Chan-Vese) refinement, enhanced by an area constraint and a gradient-based boundary selection mechanism. The procedure includes preprocessing (hair removal, illumination correction, and adaptive vignette-free region extraction), followed by FCM initialization and contour refinement. Experimental results demonstrate that the proposed method outperforms the Otsu baseline, achieving higher intra-region uniformity (0.368 vs. 0.363) and inter-region contrast (0.999 vs. 0.997), resulting in a better overall quality score (0.3675 vs. 0.3609). These findings indicate that the method produces more accurate and stable lesion segmentation. The proposed framework offers a practical solution for melanoma segmentation, particularly in scenarios where ground-truth annotations are limited.
KW - active contour chan-vese model
KW - dermoscopy image
KW - fuzzy c-means
KW - hybrid segmentation
KW - melanoma
UR - https://www.scopus.com/pages/publications/105047918689
U2 - 10.1109/ICADEIS71120.2026.11644558
DO - 10.1109/ICADEIS71120.2026.11644558
M3 - Conference contribution
AN - SCOPUS:105047918689
T3 - 2026 International Conference on Advancement in Data Science, E-Learning and Information System, ICADEIS 2026
BT - 2026 International Conference on Advancement in Data Science, E-Learning and Information System, ICADEIS 2026
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2026 International Conference on Advancement in Data Science, E-Learning and Information System, ICADEIS 2026
Y2 - 23 June 2026 through 24 June 2026
ER -