TY - GEN
T1 - Improved energy saving for R22 building air conditioning retrofitted with hydrocarbon refrigerant, Study case
T2 - International Conference on Mechanical Engineering, ICOME 2013
AU - Widyastuti,
AU - Putra, Ary Bachtiar Krishna
AU - Hantoro, Ridho
AU - Novianarenti, Eky
AU - Safitra, Arrad Ghani
PY - 2014
Y1 - 2014
N2 - Sepuluh November Institute of Technology (ITS) encourages the ECO Campus program. The program enables ITS to systematically identify, evaluate, manage and improve their environmental performance and practices. One of the program issue is energy saving in building. The energy saving effect of an air-conditioning system retrofit project is analyzed by Energy Conservation Opportunities (ECOs) Method. These ECOs are assessed in terms of their costs and benefits, and an economic comparison to rank the various refrigerants. Finally, an Action Plan is created where certain ECOs are selected for implementation. Civil Engineering Department has a responsibility to design infrastructure and green building concept planning. This department also has the largest energy consumption in this faculty comparing the other department. The energy consumption on this Department is 60829 kWh/month. The value of IKE is 13.39 per month with the largest electrical energy consumption in air-conditioning system is 57% from total consumption. The energy used of air-conditioning sytem is 523.692 kWh. The energy saving opportunities by CFC retrofitting with hydrocarbon can save its power consumption about 20%. It also saving cost and reducing the electricity bill of 1643871.838 IDR/month. The payback period of investment costs of retrofit R-22 to Hydrocarbonis about 13 month.
AB - Sepuluh November Institute of Technology (ITS) encourages the ECO Campus program. The program enables ITS to systematically identify, evaluate, manage and improve their environmental performance and practices. One of the program issue is energy saving in building. The energy saving effect of an air-conditioning system retrofit project is analyzed by Energy Conservation Opportunities (ECOs) Method. These ECOs are assessed in terms of their costs and benefits, and an economic comparison to rank the various refrigerants. Finally, an Action Plan is created where certain ECOs are selected for implementation. Civil Engineering Department has a responsibility to design infrastructure and green building concept planning. This department also has the largest energy consumption in this faculty comparing the other department. The energy consumption on this Department is 60829 kWh/month. The value of IKE is 13.39 per month with the largest electrical energy consumption in air-conditioning system is 57% from total consumption. The energy used of air-conditioning sytem is 523.692 kWh. The energy saving opportunities by CFC retrofitting with hydrocarbon can save its power consumption about 20%. It also saving cost and reducing the electricity bill of 1643871.838 IDR/month. The payback period of investment costs of retrofit R-22 to Hydrocarbonis about 13 month.
KW - Civil engineering department
KW - Energy consumption opportunities
KW - Global warming
KW - Retrofit
UR - http://www.scopus.com/inward/record.url?scp=84892866649&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMM.493.281
DO - 10.4028/www.scientific.net/AMM.493.281
M3 - Conference contribution
AN - SCOPUS:84892866649
SN - 9783037859902
T3 - Applied Mechanics and Materials
SP - 281
EP - 286
BT - Advances in Applied Mechanics and Materials
Y2 - 19 September 2013 through 21 September 2013