TY - JOUR
T1 - Moment contribution capacity of tendon prestressed partial on concrete beam-column joint interior according to provisions ACI 318-2008 Chapter 21.5.2.5(c) due to cyclic lateral loads
AU - Astawa, Made Dharma
AU - Raka, Igusti Putu
AU - Tavio,
N1 - Publisher Copyright:
© Owned by the authors, published by EDP Sciences, 2016.
PY - 2016/5/23
Y1 - 2016/5/23
N2 - This research designed a partial prestressed concrete beam-column with reinforced concrete interior joint, using square columns of 400/400 mm, reinforcement 6 D16 + 4D13, section beam 250/400 mm, tensile reinforcement 5 D13, compression reinforcement 3 D13 + 2 strand tendon D12,7 mm, and joint without plastic hinge, then tested in laboratory with lateral cyclic loads on peak column, static axial load 1120 kN on the centre column, to get the tendon capacity to assume positive and negative bending moments due to lateral load, according to provisions of ACI 318-2008 part 21.5.2.5 (c). Test results showed that the moment tendon contribution on beam section, in the tensile area, the positive and negative moment both on the left side or the right side column are all qualified (<25 %). In compression area, the positive moments on left and right columns are not qualified at all (> 25 %). As for the negative moment, either left or right side column are all qualified (< 25 %). Ductility, compression, and tensile ductility on drift ratio 3.50% are all qualified (>4.0). Although the contribution of positive moment capacity tendon in compression areas does not qualify, in overall, the reliability and ductility of the structure qualify.
AB - This research designed a partial prestressed concrete beam-column with reinforced concrete interior joint, using square columns of 400/400 mm, reinforcement 6 D16 + 4D13, section beam 250/400 mm, tensile reinforcement 5 D13, compression reinforcement 3 D13 + 2 strand tendon D12,7 mm, and joint without plastic hinge, then tested in laboratory with lateral cyclic loads on peak column, static axial load 1120 kN on the centre column, to get the tendon capacity to assume positive and negative bending moments due to lateral load, according to provisions of ACI 318-2008 part 21.5.2.5 (c). Test results showed that the moment tendon contribution on beam section, in the tensile area, the positive and negative moment both on the left side or the right side column are all qualified (<25 %). In compression area, the positive moments on left and right columns are not qualified at all (> 25 %). As for the negative moment, either left or right side column are all qualified (< 25 %). Ductility, compression, and tensile ductility on drift ratio 3.50% are all qualified (>4.0). Although the contribution of positive moment capacity tendon in compression areas does not qualify, in overall, the reliability and ductility of the structure qualify.
KW - Ductility
KW - Interior beam-column joint
KW - Partial prestressed
KW - Tendon moment contribution
UR - http://www.scopus.com/inward/record.url?scp=84974588343&partnerID=8YFLogxK
U2 - 10.1051/matecconf/20165804005
DO - 10.1051/matecconf/20165804005
M3 - Conference article
AN - SCOPUS:84974588343
SN - 2261-236X
VL - 58
JO - MATEC Web of Conferences
JF - MATEC Web of Conferences
M1 - 04005
T2 - 3rd Bali International Seminar on Science and Technology, BISSTECH 2015
Y2 - 15 October 2015 through 17 October 2015
ER -