Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter

Sutrisno*, Y. A. Laksono, N. Hidayat

*Corresponding author for this work

Research output: Contribution to journalConference articlepeer-review

7 Citations (Scopus)

Abstract

Diabetes kills millions of people worldwide each year. It challenges us as researchers to give contribution in early diagnosis to ensure a healthy life. As a matter of fact, common glucose testing devices that have been widely used so far are, at least, glucose meter and urine glucose test strip. The glucose meter ordinarily requires blood taken from patient's finger. The glucose test strip uses patient's urine but records unspecific urine glucose level, since the strip only provides the glucose level in some particular ranges. Instead of detecting the glucose level in blood and using the non-specific technique, a noninvasive and painless technique that can detect glucose level accurately will provide a more feasible approach for diabetes diagnosis. The noninvasive and painless urine glucose level monitoring by means of computer-based polarimeter is presented in this paper. The instrument consisted of a power source, a sample box, a light sensor, a polarizer, an analyzer, an analog to digital converter (ADC), and a computer. The concentration of urine glucose concentration was evaluated from the curve of the change in detected optical rotation angle and output potential by the computer-based polarimeter. Statistical analyses by means of Gaussian fitting and linear regression were applied to investigate the rotation angle and urine glucose concentration, respectively. From our experiment, the urine glucose level, measured by glucose test strips, of the normal patient was 100 mg/dl, and the diabetic patient was 500 mg/dl. Our polarimeter even read more precise values for the urine glucose concentrations of those normal and diabetic of the same patients, i.e. 50.61 mg/dl and 502.41 mg/dl, respectively. In other words, the results showed that our polarimeter was able to quantitatively measure the urine glucose level more accurate than urine glucose test strips. Hence, this computer-based polarimeter could be used as an alternative for early detection of urine glucose with noninvasive and painless characteristics.

Original languageEnglish
Article number012030
JournalIOP Conference Series: Materials Science and Engineering
Volume202
Issue number1
DOIs
Publication statusPublished - 31 May 2017
Externally publishedYes
Event4th International Conference on Advanced Materials Science and Technology 2016, ICAMST 2016 - Malang, Indonesia
Duration: 27 Sept 201628 Sept 2016

Keywords

  • computer-based polarimeter
  • glucose level
  • noninvasive and painless measurement

Fingerprint

Dive into the research topics of 'Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter'. Together they form a unique fingerprint.

Cite this