TY - JOUR
T1 - Optimal placement of SVC for losses reduction and voltage profile improvement in electrical power system using improved gravitational search algorithm
AU - Purwoharjono,
AU - Abdillah, Muhammad
AU - Penangsang, Ontoseno
AU - Soeprijanto, Adi
PY - 2013
Y1 - 2013
N2 - The development of the more increasing power electronics allows the use of FACTS devices to manage and improve either the flow of power or the stability of the power system. One type of FACTS device studied is the SVC. In this study, optimization of SVC is used to determine the most appropriate location and rating in order to obtain the optimum power transfer. Optimization methods used in this study is Improved Gravitational Search Algorithm (IGSA). Improved GSA uses Interval Type-2 Fuzzy Logic System (IT2FLS). IGSA implementation uses Java-Bali power system 500 kV. Simulation results show that the simulation results better with the use of SVC placement than with the GSA and without SVC placement. Placement of SVC with the right location and rating using the IGSA and GSA can reduce power loss in the transmission line and also can improve the voltage profile according to the standards set, in the range of 0.95 ± 1.05pu when compared without SVC.
AB - The development of the more increasing power electronics allows the use of FACTS devices to manage and improve either the flow of power or the stability of the power system. One type of FACTS device studied is the SVC. In this study, optimization of SVC is used to determine the most appropriate location and rating in order to obtain the optimum power transfer. Optimization methods used in this study is Improved Gravitational Search Algorithm (IGSA). Improved GSA uses Interval Type-2 Fuzzy Logic System (IT2FLS). IGSA implementation uses Java-Bali power system 500 kV. Simulation results show that the simulation results better with the use of SVC placement than with the GSA and without SVC placement. Placement of SVC with the right location and rating using the IGSA and GSA can reduce power loss in the transmission line and also can improve the voltage profile according to the standards set, in the range of 0.95 ± 1.05pu when compared without SVC.
KW - FACTS device
KW - Gravitational search algorithm
KW - Improved gravitational search algorithm
KW - Static var compensator
UR - http://www.scopus.com/inward/record.url?scp=84876096812&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:84876096812
SN - 1827-6660
VL - 8
SP - 329
EP - 339
JO - International Review of Electrical Engineering
JF - International Review of Electrical Engineering
IS - 1
ER -