Abstract
The aim of this research is to get the optimum operating condition of crude distillation unit in order to get the highest profit for the crude oil refinery industry. Feeds specification data are taken from an Indonesian crude oil refinery. Simulation was done by using ASPEN PLUS (Aspen Technology, Inc, Burlington, MA, USA). The design variable for this research is the temperature of preflash column furnace. Optimization was done by considering the maximum profit. Based on the result in part one, where intermediate and light cold test molar flowrates and the quality of heavy naphtha in the 95% liquid volume ASTM D86 at 415K and light kerosene distillate in the 95% liquid volume ASTM D86 at 469K are held constant, the optimum condition is found at the furnace preflash temperature of 572K with a profit of US$ 9.62 per m3 crude oil. While in part two, where heavy naphtha and light kerosene distillate molar flowrates and the quality of intermediate in the 95% liquid volume ASTMD86 at 443K and light cold test in the 95% liquid volume ASTMD86 at 605K are held constant, the optimum condition is found at the furnace preflash temperature of 533K with a profit of US$ 7.74 per m 3 crude oil.
Original language | English |
---|---|
Pages (from-to) | S78-S87 |
Journal | Asia-Pacific Journal of Chemical Engineering |
Volume | 7 |
Issue number | SUPPL. 1 |
DOIs | |
Publication status | Published - May 2012 |
Keywords
- Aspen Plus
- crude distillation unit (CDU)
- furnace
- optimization
- profit
- refinery