TY - GEN
T1 - Redesign ITS central library through smart building
AU - Junaidi, Muhammad
AU - Kusriantoko, Parindra
AU - Ardhyananta, Hosta
AU - Bachtiar, Ary
AU - Dimas, Anton A.
PY - 2014
Y1 - 2014
N2 - Energy conservation is one of many technique applied to reduce the global warming effect. Sepuluh Nopember Institute of Technology (ITS) contributes to encourage energy conservation by ITS Eco Campus programs. It has so many activities, one of them is audit energy as one way to get energy efficiency in educational area. ITS central library is most accessable building both student and other academics community with total area more than 400 square matres and high occupation rate approximately 90% everyday. Energy audit techniques were carried out by an energy audit team to identify any energy conservation opportunities (ECOs). walk-through assessment and data analysis were conducted over all building zones. These levels of assessments proved that the building and its mechanical and electrical systems were improperly maintained and inefficiently operated. So that, ITS Central Library will be redesigned to be smart building by improving light intentensity level, humidity, and room temperature appropriate with ASHRAE 90.1-2005. Thus exterior building like wall, glass, roof and floor will be redesigned to emphasize minimum total load. Replacement single glass to double glass reduce the load conduction and radiation through glass, approximately 2,7%.
AB - Energy conservation is one of many technique applied to reduce the global warming effect. Sepuluh Nopember Institute of Technology (ITS) contributes to encourage energy conservation by ITS Eco Campus programs. It has so many activities, one of them is audit energy as one way to get energy efficiency in educational area. ITS central library is most accessable building both student and other academics community with total area more than 400 square matres and high occupation rate approximately 90% everyday. Energy audit techniques were carried out by an energy audit team to identify any energy conservation opportunities (ECOs). walk-through assessment and data analysis were conducted over all building zones. These levels of assessments proved that the building and its mechanical and electrical systems were improperly maintained and inefficiently operated. So that, ITS Central Library will be redesigned to be smart building by improving light intentensity level, humidity, and room temperature appropriate with ASHRAE 90.1-2005. Thus exterior building like wall, glass, roof and floor will be redesigned to emphasize minimum total load. Replacement single glass to double glass reduce the load conduction and radiation through glass, approximately 2,7%.
KW - Energy audit
KW - Energy conservation
KW - ITS central library
UR - http://www.scopus.com/inward/record.url?scp=84892875661&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMM.493.117
DO - 10.4028/www.scientific.net/AMM.493.117
M3 - Conference contribution
AN - SCOPUS:84892875661
SN - 9783037859902
T3 - Applied Mechanics and Materials
SP - 117
EP - 122
BT - Advances in Applied Mechanics and Materials
T2 - International Conference on Mechanical Engineering, ICOME 2013
Y2 - 19 September 2013 through 21 September 2013
ER -