TY - GEN
T1 - Security constrained dynamic optimal power flow with multiple energy storage
AU - Wibowo, Rony Seto
AU - Nugraha, Yoanes Bagus
AU - Asfani, Dimas Anton
AU - Penangsang, Ontoseno
AU - Aryani, Ni Ketut
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/12/19
Y1 - 2017/12/19
N2 - Contingency may occur at specific time during the operation time. This paper proposes an approach for dynamic optimal power flow considering contingency states. In general, contingency can affect the operation cost. The more severe contingency can lead to the higher operation cost. When contingency occurs, generator must perform a re-dispatch to ensure all constraints satisfied. The constraints include transmission limit, ramp rate and generator limit. Re-dispatch tends to result in high generation cost. Therefore, energy storages are required to reduce the re-dispatch cost. In this paper, Quadratic Programing is applied to solve the problem formulated as security constrained dynamic optimal power flow with multiple energy storage. Modified IEEE 30 bus system is used as a test system to show the ability of the proposed approach.
AB - Contingency may occur at specific time during the operation time. This paper proposes an approach for dynamic optimal power flow considering contingency states. In general, contingency can affect the operation cost. The more severe contingency can lead to the higher operation cost. When contingency occurs, generator must perform a re-dispatch to ensure all constraints satisfied. The constraints include transmission limit, ramp rate and generator limit. Re-dispatch tends to result in high generation cost. Therefore, energy storages are required to reduce the re-dispatch cost. In this paper, Quadratic Programing is applied to solve the problem formulated as security constrained dynamic optimal power flow with multiple energy storage. Modified IEEE 30 bus system is used as a test system to show the ability of the proposed approach.
KW - DDCOPF
KW - energy storage
KW - quadratic programming
KW - securtity constraint
UR - http://www.scopus.com/inward/record.url?scp=85044217403&partnerID=8YFLogxK
U2 - 10.1109/TENCON.2017.8228166
DO - 10.1109/TENCON.2017.8228166
M3 - Conference contribution
AN - SCOPUS:85044217403
T3 - IEEE Region 10 Annual International Conference, Proceedings/TENCON
SP - 1885
EP - 1889
BT - TENCON 2017 - 2017 IEEE Region 10 Conference
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2017 IEEE Region 10 Conference, TENCON 2017
Y2 - 5 November 2017 through 8 November 2017