T1 - Simulation of the Drying Process of Polysaccharide Extract Solution in a Spray Dryer
AU - Nurtono, Tantular
AU - Widiyastuti, Widiyastuti
AU - Mufyda Rahmatika, Annie
AU - Machmudah, Siti
AU - Winardi, Sugeng
N1 - Publisher Copyright:
© 2020 IOP Publishing Ltd.
PY - 2020/4/30
Y1 - 2020/4/30
N2 - The drying process of droplets into particles on a spray dryer is influenced by several factors, including the temperature and the flow rate of inlet air as a carrier gas and a drying media. The effects of temperature of the inlet air in the spray dryer system was elucidated in this study. A solution containing 35 w% polysaccharide extract and water as the solvent was injected into a spray dryer. The inlet air temperatures were varied at 135, 170, and 200 °C with 3 L/min. The geometry of spray dryer consisted of the tubular-conical with a length of 48.8 cm and 15.2 cm diameter cylinder. The spray dryer unit was simulated using CFD code, Fluent Ansys R15.0 with the second phase of droplets/particles was modelled by the Lagrangian discrete phase model (DPM). The inlet air temperature also affected the size of the particles. The increase of the air temperature led to the increase of the average particle diameter leaving the chamber with the smaller standard deviation. The air flow rate affected the particle size. The higher the air flow rate, the smaller the size of the average diameter of the particles and smaller standard deviation would be. The evaporation rate increased with the increase of the flow rate and inlet air temperature. The resulting particles had an average size of 1.28∼1.9 μm diameter to drying with hot air that flowed continuously. The simulation result was validated by the experimental work with discrepancy less than 20%.
AB - The drying process of droplets into particles on a spray dryer is influenced by several factors, including the temperature and the flow rate of inlet air as a carrier gas and a drying media. The effects of temperature of the inlet air in the spray dryer system was elucidated in this study. A solution containing 35 w% polysaccharide extract and water as the solvent was injected into a spray dryer. The inlet air temperatures were varied at 135, 170, and 200 °C with 3 L/min. The geometry of spray dryer consisted of the tubular-conical with a length of 48.8 cm and 15.2 cm diameter cylinder. The spray dryer unit was simulated using CFD code, Fluent Ansys R15.0 with the second phase of droplets/particles was modelled by the Lagrangian discrete phase model (DPM). The inlet air temperature also affected the size of the particles. The increase of the air temperature led to the increase of the average particle diameter leaving the chamber with the smaller standard deviation. The air flow rate affected the particle size. The higher the air flow rate, the smaller the size of the average diameter of the particles and smaller standard deviation would be. The evaporation rate increased with the increase of the flow rate and inlet air temperature. The resulting particles had an average size of 1.28∼1.9 μm diameter to drying with hot air that flowed continuously. The simulation result was validated by the experimental work with discrepancy less than 20%.
UR - http://www.scopus.com/inward/record.url?scp=85084316640&partnerID=8YFLogxK
U2 - 10.1088/1757-899X/778/1/012168
DO - 10.1088/1757-899X/778/1/012168
M3 - Conference article
AN - SCOPUS:85084316640
SN - 1757-8981
VL - 778
JO - IOP Conference Series: Materials Science and Engineering
JF - IOP Conference Series: Materials Science and Engineering
IS - 1
M1 - 012168
T2 - 26th Regional Symposium on Chemical Engineering, RSCE 2019
Y2 - 30 October 2019 through 1 November 2019
ER -