TY - GEN
T1 - Strain gage for mass sensor using cantilever beam
AU - Suryana, Anang
AU - Muntini, Melania Suweni
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/7/2
Y1 - 2017/7/2
N2 - Mass measuring devices have been developed by various methods. In its design, gauge the mass of the object to be adjusted in good measure the reach and shape. This corresponds to a sensitivity that can be generated by the mass measurement. One of the transducers for the measurement of mass that can detect small mass changes are the strain gage. In the making mass sensor using a strain gage type uniaxial with 120 ohm resistance and cantilever beam with a length of 2 cm, width 1 cm, thickness of 20μm that utilizes the deflection of the beam surface. The existence of deflection caused by the addition of mass at one end of the beam. Calibrated using the masses as loading balance brand ohaus Pioneer™ type PA214. Deflection that occurs detected a strain by strain gage transducers mounted on the cantilever surface. Through electronic wheatstone bridge circuit, the characteristic equation obtained by measuring the mass of the prototype instrument that states the relationship between voltage, V in millivolts, and the mass, m in grams, is V = -3.36667 m + 38.49556. This research will also be carried out data acquisition system to a PC to be stored in a database.
AB - Mass measuring devices have been developed by various methods. In its design, gauge the mass of the object to be adjusted in good measure the reach and shape. This corresponds to a sensitivity that can be generated by the mass measurement. One of the transducers for the measurement of mass that can detect small mass changes are the strain gage. In the making mass sensor using a strain gage type uniaxial with 120 ohm resistance and cantilever beam with a length of 2 cm, width 1 cm, thickness of 20μm that utilizes the deflection of the beam surface. The existence of deflection caused by the addition of mass at one end of the beam. Calibrated using the masses as loading balance brand ohaus Pioneer™ type PA214. Deflection that occurs detected a strain by strain gage transducers mounted on the cantilever surface. Through electronic wheatstone bridge circuit, the characteristic equation obtained by measuring the mass of the prototype instrument that states the relationship between voltage, V in millivolts, and the mass, m in grams, is V = -3.36667 m + 38.49556. This research will also be carried out data acquisition system to a PC to be stored in a database.
KW - Cantilever beam
KW - Mass sensor
KW - Strain gage
KW - Transducer
KW - Wheatstone bridges
UR - https://www.scopus.com/pages/publications/85050805848
U2 - 10.1109/CED.2017.8308103
DO - 10.1109/CED.2017.8308103
M3 - Conference contribution
AN - SCOPUS:85050805848
T3 - 3rd International Conference on Computing, Engineering, and Design, ICCED 2017
SP - 1
EP - 4
BT - 3rd International Conference on Computing, Engineering, and Design, ICCED 2017
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 3rd International Conference on Computing, Engineering, and Design, ICCED 2017
Y2 - 23 November 2017 through 25 November 2017
ER -