TY - GEN
T1 - Synthesis of carbon dots from organic waste as heavy metal ions detector sensor
AU - Sawitri, Dyah
AU - Nurfathiya, Nadhira
AU - Isnaeni,
AU - Adziimaa, Ahmad Fauzan
N1 - Publisher Copyright:
© 2019 SPIE.
PY - 2019
Y1 - 2019
N2 - The comparison between two different bottom-up synthetic techniques had been prepared in order to synthesis the carbon dots (CD) from organic waste, i.e. the hydrothermal (HT) and microwave irradiation (MI) techniques. The CD were extracted from two different sources, i.e. from watermelon rind (wet organic waste) and peanut skin (dry organic waste). All of the products were characterized using spectroscopy characterization to determine their optical characteristics. It was obtained that all of the CD absorbing light in the UV region (around 300 nm) and emitting light in the visible light region (around 500 nm) which is called as photoluminescence (PL). The time-resolved PL (TRPL) was also observed within all of the products, which shows that they have TRPL around 3 to 4 ns, thus those CD categorized as fluorescence. Then, both CD from watermelon rind (WR) and peanut skin (PS) were examined using FTIR and it was obtained that both CD has carboxyl group content. After that, both products were also compared based on their performance as Fe3+ and Pb2+ sensors (1 nM-10-1 M with 10 interval). The best performance was achieved by PS CD, due to its consistency in optical characteristics degradations (negative degradation) due to PL-turn off sensor method with the regression of each optical characteristics (absorbance, PL, and TRPL) are 0.6542, 0.6567, and 0.6168.
AB - The comparison between two different bottom-up synthetic techniques had been prepared in order to synthesis the carbon dots (CD) from organic waste, i.e. the hydrothermal (HT) and microwave irradiation (MI) techniques. The CD were extracted from two different sources, i.e. from watermelon rind (wet organic waste) and peanut skin (dry organic waste). All of the products were characterized using spectroscopy characterization to determine their optical characteristics. It was obtained that all of the CD absorbing light in the UV region (around 300 nm) and emitting light in the visible light region (around 500 nm) which is called as photoluminescence (PL). The time-resolved PL (TRPL) was also observed within all of the products, which shows that they have TRPL around 3 to 4 ns, thus those CD categorized as fluorescence. Then, both CD from watermelon rind (WR) and peanut skin (PS) were examined using FTIR and it was obtained that both CD has carboxyl group content. After that, both products were also compared based on their performance as Fe3+ and Pb2+ sensors (1 nM-10-1 M with 10 interval). The best performance was achieved by PS CD, due to its consistency in optical characteristics degradations (negative degradation) due to PL-turn off sensor method with the regression of each optical characteristics (absorbance, PL, and TRPL) are 0.6542, 0.6567, and 0.6168.
KW - Carbon Dots
KW - Ferric (Fe). Pb
KW - Heavy Metal Detection
KW - Organic Waste
KW - Sensor
UR - http://www.scopus.com/inward/record.url?scp=85065614001&partnerID=8YFLogxK
U2 - 10.1117/12.2504482
DO - 10.1117/12.2504482
M3 - Conference contribution
AN - SCOPUS:85065614001
T3 - Proceedings of SPIE - The International Society for Optical Engineering
BT - Third International Seminar on Photonics, Optics, and Its Applications, ISPhOA 2018
A2 - Hatta, Agus Muhammad
A2 - Nasution, Aulia
PB - SPIE
T2 - 3rd International Seminar on Photonics, Optics, and Its Applications, ISPhOA 2018
Y2 - 1 August 2018 through 2 August 2018
ER -