Tensile Strength of Porcine Aorta Decellularized with Liquefied Dimethyl Ether and DNase

  • Hideki Kanda*
  • , Kento Oya
  • , Toshihira Irisawa
  • , Wahyudiono
  • , Motonobu Goto
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

6 Citations (Scopus)

Abstract

In a previous report, we proposed a method for decellularizing porcine aortas by removing lipids from the aortas using liquefied dimethyl ether (DME) instead of the conventional sodium dodecyl sulfate (SDS). This is followed by DNA fragmentation with DNase. In the current work, the physical properties of porcine aortas decellularized using the DME method are evaluated by tensile strength tests. Conventional SDS decellularized aortas are typically swollen, rupture very easily, and have poor elasticity. By contrast, DME-treated samples are found to be less elastic. However, the maximum stress required for rupture is greater than that for the original aorta. These results indicate that decellularization with DME and DNase increases the maximum stress that can be withstood. Reduction of elasticity may derive from the appearance of temporary C═N bonds due to Schiff-base reactions that occur during the lipid removal process by liquefied DME, and methods to avoid this are desirable.

Original languageEnglish
Pages (from-to)34449-34453
Number of pages5
JournalACS Omega
Volume7
Issue number38
DOIs
Publication statusPublished - 27 Sept 2022
Externally publishedYes

Fingerprint

Dive into the research topics of 'Tensile Strength of Porcine Aorta Decellularized with Liquefied Dimethyl Ether and DNase'. Together they form a unique fingerprint.

Cite this