TY - JOUR
T1 - The correlation of EDT and T30 result of YMEC measurement compared with RT sabine theory and eyring in semi-anechoic room in physics department Institut Teknologi Sepuluh Nopember
AU - Indrawati, Susilo
AU - Muntini, Melania Suweni
AU - Fatimah, Iim
AU - Anggoro, Diky
AU - Sudarsono,
AU - Puspitasari, Nurrisma
AU - Haikal, Yusuf
AU - Suyatno,
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2019/2/26
Y1 - 2019/2/26
N2 - In the science of acoustics required two special rooms namely Reverberation Chamber and Anechoic Room. In Anechoic room is a free field from the reflection of sound so this room used to examine signals in audiosonics. one of which can be used to evaluate the noise of a machine and the analysis of acoustic materials. The calculation approach of Reverberation time is based on the semi-empirical formulation of Sabine and Eyring's theory. Measurement software used YMEC, can determine the time of buzzing EDT and T30. This research was conducted in semi-an echoic room department of physics ITS. From the measurement results obtained, cutoff frequency value of 23 Hz and critical frequency 200 Hz. The correlation of EDT and T30 results of Measurement of YMEC compared with the Reverberation time of Sabine and Eyring's Theory. Based on the measurement results obtained the corresponding reverberation time is EDT using Eyring theory approach method. Measurement T30 has almost the same value, but at 4000 Hz frequency experienced a significant increase. Reverberation time using the Sabine or Eyring theory has the same curve but for the value obtained Eyring theory is closer to the value of EDT.
AB - In the science of acoustics required two special rooms namely Reverberation Chamber and Anechoic Room. In Anechoic room is a free field from the reflection of sound so this room used to examine signals in audiosonics. one of which can be used to evaluate the noise of a machine and the analysis of acoustic materials. The calculation approach of Reverberation time is based on the semi-empirical formulation of Sabine and Eyring's theory. Measurement software used YMEC, can determine the time of buzzing EDT and T30. This research was conducted in semi-an echoic room department of physics ITS. From the measurement results obtained, cutoff frequency value of 23 Hz and critical frequency 200 Hz. The correlation of EDT and T30 results of Measurement of YMEC compared with the Reverberation time of Sabine and Eyring's Theory. Based on the measurement results obtained the corresponding reverberation time is EDT using Eyring theory approach method. Measurement T30 has almost the same value, but at 4000 Hz frequency experienced a significant increase. Reverberation time using the Sabine or Eyring theory has the same curve but for the value obtained Eyring theory is closer to the value of EDT.
UR - http://www.scopus.com/inward/record.url?scp=85062872591&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/1153/1/012002
DO - 10.1088/1742-6596/1153/1/012002
M3 - Conference article
AN - SCOPUS:85062872591
SN - 1742-6588
VL - 1153
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012002
T2 - 9th International Conference on Physics and Its Applications, ICOPIA 2018
Y2 - 14 August 2018 through 14 August 2018
ER -