TY - JOUR
T1 - The vented-box effect on thiele-small parameter loudspeaker
AU - Suyatno,
AU - Putrie, W. P.
AU - Indrawati, S.
AU - Prajitno, G.
N1 - Publisher Copyright:
© 2021 Institute of Physics Publishing. All rights reserved.
PY - 2021/3/12
Y1 - 2021/3/12
N2 - Loudspeakertesting is usually using the Thiele-smallparameter.To see the effect of the vented boxon loudspeakerquality,Thiele-smallparametersin vented boxboxes are used. Research carried out by measuring the characteristics of loudspeaker response frequency, impedance,and Thiele smallparameters in vented-boxesand panels. One factor affecting the acoustic parametersis the compressedairvalue generated by the loudspeaker or so-called air compliance.In vented-boxes,there is an effect of compressed air compliance in the boxand the air coming from the hole which is causing the pure loudspeaker sound trigger. On the panel, there is no compressed air. Fromthe measurement and results analysis, the ratio of compliance fromthe boxis 8.29: 10.7. This value has impacted the losses of the vented-box. The losses ofthevented-boxare 0.63% and the losses that happened on the panel is 0,014%. The losses oftheenclosure are causedby the shape ofthe enclosure design and the damping material in it.
AB - Loudspeakertesting is usually using the Thiele-smallparameter.To see the effect of the vented boxon loudspeakerquality,Thiele-smallparametersin vented boxboxes are used. Research carried out by measuring the characteristics of loudspeaker response frequency, impedance,and Thiele smallparameters in vented-boxesand panels. One factor affecting the acoustic parametersis the compressedairvalue generated by the loudspeaker or so-called air compliance.In vented-boxes,there is an effect of compressed air compliance in the boxand the air coming from the hole which is causing the pure loudspeaker sound trigger. On the panel, there is no compressed air. Fromthe measurement and results analysis, the ratio of compliance fromthe boxis 8.29: 10.7. This value has impacted the losses of the vented-box. The losses ofthevented-boxare 0.63% and the losses that happened on the panel is 0,014%. The losses oftheenclosure are causedby the shape ofthe enclosure design and the damping material in it.
UR - http://www.scopus.com/inward/record.url?scp=85103271063&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/1825/1/012002
DO - 10.1088/1742-6596/1825/1/012002
M3 - Conference article
AN - SCOPUS:85103271063
SN - 1742-6588
VL - 1825
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012002
T2 - 10th International Conference on Physics and Its Applications, ICOPIA 2020
Y2 - 26 August 2020
ER -