Venous Chamber Pressure Control and Air Bubbles Detection in Hemodialysis Delivery System Based on Fuzzy Logic

Muhammad Hilman Fatoni, Firdausi Nuzula Alghozali, Rachmad Setiawan

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Air bubbles can enter the exctracorporeal hemodialysis circuit because of air trapped inside the tubing or because of a faulty pump connection. If a considerably dangerous amount of air bubble were to enter the veins, the patient will most likely to experience venous air embolism (VAE). To avoid the possibility of VAE, an air bubble detection along with an automatic clamping system is needed right before the blood is returned to the patients vein. A sudden change of venous chamber pressure during hemodalysis may cause hemolysis. This change of pressure can be caused by a kink in the venous chamber tubing, clotting in the patient's venous access, or a change in blood pump speed. A pressure sensor is required to monitor the pressure inside the hemodialysis venous chamber before the blood enters the vein. This study propose a device to monitor venous chamber pressure and detect air bubbles in the hemodialysis delivery system based on fuzzy logic. The pressure error and derivative error to the ideal pressure measured by the sensor will be the input of a DC motor speed control system to drive the peristaltic pump based on fuzzy logic controller (FLC). Output value of the designed FLC is Pulse Width Modulation (PWM) signal using a pressure sensor as the feedback. Air bubble detection is done by utilizing an air bubble sensor. Based on the DC motor test, saturation of rotation speed (RPM) occurs when given duty cycle of 84,3% and above. This was used as a consideration during the development of the fuzzy logic parameters, which results in the duty cycle given is between 65%-70%. The system needs 72,42 seconds to return to the set point when given disruption in the form of sudden increased pressure. It also needs 28,755 seconds to return to the set point when given disruption in the form of sudden pressure loss.

Original languageEnglish
Title of host publicationProceeding of the International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2022
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages99-103
Number of pages5
ISBN (Electronic)9781665476508
DOIs
Publication statusPublished - 2022
Event2022 International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2022 - Surabaya, Indonesia
Duration: 22 Nov 202223 Nov 2022

Publication series

NameProceeding of the International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2022

Conference

Conference2022 International Conference on Computer Engineering, Network and Intelligent Multimedia, CENIM 2022
Country/TerritoryIndonesia
CitySurabaya
Period22/11/2223/11/22

Keywords

  • DC motor
  • air bubbles
  • fuzzy logic controller
  • hemodialysis
  • venous chamber

Fingerprint

Dive into the research topics of 'Venous Chamber Pressure Control and Air Bubbles Detection in Hemodialysis Delivery System Based on Fuzzy Logic'. Together they form a unique fingerprint.

Cite this